SR4P2A1B24N
UsedformonitoringdualNPNoutputsafetylightcurtains.Features:1、Detectableshortcircuitfaultsininputcontacts;2、Canchoosebetweencontrolledmanualresetandautomaticreset;3、Circuitwithselfmonitoring;4、Realtime...
Used for monitoring dual NPN output safety light curtains.
Features:
1、Detectable short circuit faults in input contacts;
2、Can choose between controlled manual reset and automatic reset;
3、Circuit with self monitoring;
4、Real time monitoring of working status。
Performance Level:?
Ple;Security category:Cat.4; SIL3
Technical Parameter:
model | SR4P2A1B24N |
RESET MODE | Manual or automatic |
Working power supply | DC24V |
consumption | 3W |
Output contact | 2N/O,1N/C |
switching capacity | AC-15,5A/250V;?DC-13,6A/24V |
Release buffer time | <15ms |
Diagnostic Coverage | >99% |
Mean time between dangerous failures | 374a |
Average hourly hazardous failure rate | 2.6×10-8 |
protection grade | IP50 |
operation temperature | ??-10?~+55℃ |
storage temperature | ??-40?~+85℃ |
Wire cross-sectional area | Max.?2.5mm2 |
Length | Longest Max.?100m |
size | 96(L)×22.5(W)×116(H)mm |
Compliant with standards | EN?60947-5-1,?EN?61000-6-2,?EN?61000-6-3,??IEC/EN?60204-1,?EN?ISO?13849-1,?EN?574 |
?